aboutsummaryrefslogtreecommitdiffstats
path: root/tests/tc100_instructions/insn_CALL.awl
blob: 04126a928bcc2dc55ab5e0fddf0898c18ce89bfe (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
DATA_BLOCK DB 1
STRUCT
	Value		: INT;
	VAR0		: INT;
END_STRUCT;
BEGIN
	Value		:= 8290;
	VAR0		:= 0;
END_DATA_BLOCK


FUNCTION_BLOCK FB 1
BEGIN
	__ASSERT==	__AR 2,		P#42.0 // Check AR2 magic

	L		W#16#4321
	T		MW 0
END_FUNCTION_BLOCK


FUNCTION FC 1 : VOID
BEGIN
	__ASSERT==	__AR 2,		P#42.0 // Check AR2 magic

	L		W#16#1234
	T		MW 0
	CALL		FC 2
END_FUNCTION


FUNCTION FC 2 : VOID
BEGIN
	__ASSERT==	__AR 2,		P#42.0 // Check AR2 magic

	L		W#16#6789
	T		MW 0
	L		10
	T		LB 0
END_FUNCTION


FUNCTION FC 3 : VOID
BEGIN
	__ASSERT==	__AR 2,		P#42.0 // Check AR2 magic

	L		1
	T		LB 0
	CALL		FC 2
	__ASSERT==	LB 0,	1
END_FUNCTION


FUNCTION FC 4 : VOID
VAR_INPUT
	INPVAR		: INT;
	INPVAR3		: BOOL;
	INPVAR4		: BOOL;
END_VAR
VAR_IN_OUT
	INOUT0		: INT;
	INOUT1		: INT;
END_VAR
BEGIN
	__ASSERT==	__AR 2,		P#42.0 // Check AR2 magic

	// Check interface
	L		#INPVAR
	__ASSERT==	__ACCU 1,	9976
	U		#INPVAR3
	__ASSERT==	__STW VKE,	0
	U		#INPVAR4
	__ASSERT==	__STW VKE,	1
	L		#INOUT0
	__ASSERT==	__ACCU 1,	84
	L		#INOUT1
	__ASSERT==	__ACCU 1,	984

	L		42
	T		#INOUT0
	L		942
	T		#INOUT1
END_FUNCTION


FUNCTION FC 5 : VOID
VAR_INPUT
	INPVAR2		: INT;
	INPVAR3		: BOOL;
	INPVAR4		: BOOL;
END_VAR
VAR_IN_OUT
	INOUT0		: INT;
	INOUT1		: INT;
END_VAR
BEGIN
	__ASSERT==	__AR 2,		P#42.0 // Check AR2 magic

	// Check interface
	L		#INOUT0
	__ASSERT==	__ACCU 1,	84
	L		#INOUT1
	__ASSERT==	__ACCU 1,	984

	CALL FC 4 (
		INPVAR		:= #INPVAR2,	// This is a parameter
		INPVAR3		:= #INPVAR3,
		INPVAR4		:= #INPVAR4,
		INOUT0		:= #INOUT0,
		INOUT1		:= #INOUT1,
	)

	L		#INOUT0
	__ASSERT==	__ACCU 1,	42
	L		168
	T		#INOUT0
	L		#INOUT1
	__ASSERT==	__ACCU 1,	942
	L		9168
	T		#INOUT1
END_FUNCTION


FUNCTION FC 6 : VOID
BEGIN
	__ASSERT==	__AR 2,		P#42.0 // Check AR2 magic

	// Only check OV and OS bits
	__ASSERT==	__STW OV,	1
	__ASSERT==	__STW OS,	0
	L		1
	L		1
	+I
	__ASSERT==	__STW OV,	0
	__ASSERT==	__STW OS,	0
END_FUNCTION


FUNCTION FC 7 : VOID
BEGIN
	__ASSERT==	__AR 2,		P#42.0 // Check AR2 magic

	// Trigger an overflow
	__ASSERT==	__STW OV,	0
	__ASSERT==	__STW OS,	0
	L		30000
	L		30000
	+I
	__ASSERT==	__STW OV,	1
	__ASSERT==	__STW OS,	1
END_FUNCTION


FUNCTION_BLOCK FB 10
VAR_INPUT
	INVAR1		: BOOL;
	INVAR2		: BYTE;
	INVAR3		: WORD;
	INVAR4		: DWORD;
	INVAR5		: INT;
	INVAR6		: DINT;
	INVAR7		: REAL;
	INVAR8		: S5TIME;
	INVAR9		: TIME;
	INVAR10		: DATE;
	INVAR11		: CHAR;
END_VAR
VAR_OUTPUT
	RETURNVALUE	: INT;
END_VAR
BEGIN
	// This FB is CALLed. Check multi instance base register addresse.
	__ASSERT==	__AR 2,		P#DBX 0.0

	// Check parameter values
	U		#INVAR1
	__ASSERT==	__STW VKE,	1
	L		#INVAR2
	__ASSERT==	__ACCU 1,	B#16#12
	L		#INVAR3
	__ASSERT==	__ACCU 1,	W#16#3456
	L		#INVAR4
	__ASSERT==	__ACCU 1,	DW#16#88776655
	L		#INVAR5
	__ASSERT==	__ACCU 1,	8290
	L		#INVAR6
	__ASSERT==	__ACCU 1,	L#999999
	L		#INVAR7
	__ASSERT==	__ACCU 1,	9.876
	L		#INVAR8
	__ASSERT==	__ACCU 1,	S5T#9s
	L		#INVAR9
	__ASSERT==	__ACCU 1,	T#9s
	L		#INVAR10
	__ASSERT==	__ACCU 1,	900
	L		#INVAR11
	__ASSERT==	__ACCU 1,	'c'
	CALL FC 10 (
		INPUTVAR1	:= #INVAR1,
		INPUTVAR2	:= #INVAR2,
		INPUTVAR3	:= #INVAR3,
		INPUTVAR4	:= #INVAR4,
		INPUTVAR5	:= #INVAR5,
		INPUTVAR6	:= #INVAR6,
		INPUTVAR7	:= #INVAR7,
		INPUTVAR8	:= #INVAR8,
		INPUTVAR9	:= #INVAR9,
		INPUTVAR10	:= #INVAR10,
		INPUTVAR11	:= #INVAR11,
		INVAR_DB	:= DB1.DBW 0,
		RET_VAL		:= #RETURNVALUE,
	)

	// AR2 should still be the multi-instance base register, even if it
	// was clobbered in a called FC/FB.
	__ASSERT==	__AR 2,		P#DBX 0.0
END_FUNCTION_BLOCK


DATA_BLOCK DB 10
FB 10
BEGIN
END_DATA_BLOCK


FUNCTION FC 10 : INT
VAR_INPUT
	INPUTVAR1	: BOOL;
	INPUTVAR2	: BYTE;
	INPUTVAR3	: WORD;
	INPUTVAR4	: DWORD;
	INPUTVAR5	: INT;
	INPUTVAR6	: DINT;
	INPUTVAR7	: REAL;
	INPUTVAR8	: S5TIME;
	INPUTVAR9	: TIME;
	INPUTVAR10	: DATE;
	INPUTVAR11	: CHAR;
	INVAR_DB	: INT;
END_VAR
BEGIN
	// This FC is called from an FB. Thus it has the multi-instance base in AR2.
	__ASSERT==	__AR 2,		P#DBX 0.0

	// Check parameter values
	U		#INPUTVAR1
	__ASSERT==	__STW VKE,	1
	L		#INPUTVAR2
	__ASSERT==	__ACCU 1,	B#16#12
	L		#INPUTVAR3
	__ASSERT==	__ACCU 1,	W#16#3456
	L		#INPUTVAR4
	__ASSERT==	__ACCU 1,	DW#16#88776655
	L		#INPUTVAR5
	__ASSERT==	__ACCU 1,	8290
	L		#INPUTVAR6
	__ASSERT==	__ACCU 1,	L#999999
	L		#INPUTVAR7
	__ASSERT==	__ACCU 1,	9.876
	L		#INPUTVAR8
	__ASSERT==	__ACCU 1,	S5T#9s
	L		#INPUTVAR9
	__ASSERT==	__ACCU 1,	T#9s
	L		#INPUTVAR10
	__ASSERT==	__ACCU 1,	900
	L		#INPUTVAR11
	__ASSERT==	__ACCU 1,	'c'

	L		#INVAR_DB
	__ASSERT==	__ACCU 1,	8290


	// Check parameter pointers
	L		P##INPUTVAR1
	UD		DW#16#FFF80000
	__ASSERT==	__ACCU 1,	DW#16#87000000
	L		P##INPUTVAR2
	UD		DW#16#FFF80000
	__ASSERT==	__ACCU 1,	DW#16#87000000
	L		P##INPUTVAR3
	UD		DW#16#FFF80000
	__ASSERT==	__ACCU 1,	DW#16#87000000
	L		P##INPUTVAR4
	UD		DW#16#FFF80000
	__ASSERT==	__ACCU 1,	DW#16#87000000
	L		P##INPUTVAR5
	UD		DW#16#FFF80000
	__ASSERT==	__ACCU 1,	DW#16#87000000
	L		P##INPUTVAR6
	UD		DW#16#FFF80000
	__ASSERT==	__ACCU 1,	DW#16#87000000
	L		P##INPUTVAR7
	UD		DW#16#FFF80000
	__ASSERT==	__ACCU 1,	DW#16#87000000
	L		P##INPUTVAR8
	UD		DW#16#FFF80000
	__ASSERT==	__ACCU 1,	DW#16#87000000
	L		P##INPUTVAR9
	UD		DW#16#FFF80000
	__ASSERT==	__ACCU 1,	DW#16#87000000
	L		P##INPUTVAR10
	UD		DW#16#FFF80000
	__ASSERT==	__ACCU 1,	DW#16#87000000
	L		P##INPUTVAR11
	UD		DW#16#FFF80000
	__ASSERT==	__ACCU 1,	DW#16#87000000


	// Handle and check return value
	L		99
	T		#RET_VAL
	L		#RET_VAL
	__ASSERT==	__ACCU 1,	99
	L		P##RET_VAL
	UD		DW#16#FFF80000
	__ASSERT==	__ACCU 1,	DW#16#87000000


	// And another nested call
	CALL FC 11 (
		IN1	:= #INVAR_DB,
	)

	// Clobber the multi-instance base
	LAR2		P#84.0
END_FUNCTION


FUNCTION FC 11 : VOID
VAR_INPUT
	IN1		: INT;
END_VAR
BEGIN
	// This FC is called from an FB via FC. Thus it has the multi-instance base in AR2.
	__ASSERT==	__AR 2,		P#DBX 0.0

	L		#IN1
	__ASSERT==	__ACCU 1,	8290
END_FUNCTION


ORGANIZATION_BLOCK OB 1
BEGIN
	LAR2		P#42.0	// Magic AR2 value


	CALL		FC 1
	__ASSERT==	MW 0,	W#16#6789
	L		0
	T		MW 0
	__ASSERT==	MW 0,	0
	UC		FC 1
	__ASSERT==	MW 0,	W#16#6789
	L		0
	T		MW 0
	__ASSERT==	MW 0,	0
	SET
	CC		FC 1
	__ASSERT==	MW 0,	W#16#6789
	L		0
	T		MW 0
	__ASSERT==	MW 0,	0
	CLR
	CC		FC 1
	__ASSERT==	MW 0,	0

	__ASSERT==	__AR 2,		P#42.0 // Check AR2 magic

	// Test localdata stack
	L		255
	T		LB 0
	__ASSERT==	LB 0,	255
	CALL		FC 3
	__ASSERT==	LB 0,	255

	__ASSERT==	__AR 2,		P#42.0 // Check AR2 magic


	// Test nested FC calls
	L		84
	T		MW 42
	L		984
	T		DB1.DBW 2
	CALL FC 5 (
		INPVAR2		:= 9976,
		INPVAR3		:= FALSE,
		INPVAR4		:= TRUE,
		INOUT0		:= MW 42,
		INOUT1		:= DB1.DBW 2, // DB1.VAR0
	)
	L		MW 42
	__ASSERT==	__ACCU 1,	168
	L		DB1.DBW 2
	__ASSERT==	__ACCU 1,	9168

	__ASSERT==	__AR 2,		P#42.0 // Check AR2 magic


	// Test OV/OS bits over call boundaries
	__STWRST
	L		30000
	L		30000
	+I
	__ASSERT==	__STW OV,	1
	__ASSERT==	__STW OS,	1
	CALL FC 6
	__ASSERT==	__STW OV,	0
	__ASSERT==	__STW OS,	0
	__STWRST
	CALL FC 7
	__ASSERT==	__STW OV,	1
	__ASSERT==	__STW OS,	0

	__ASSERT==	__AR 2,		P#42.0 // Check AR2 magic


	// Test raw FB call
	L		0
	T		MW 0
	CLR
	UC		FB 1
	L		MW 0
	__ASSERT==	__ACCU 1,	W#16#4321
	L		0
	T		MW 0
	SET
	CC		FB 1
	L		MW 0
	__ASSERT==	__ACCU 1,	W#16#4321

	__ASSERT==	__AR 2,		P#42.0 // Check AR2 magic


	// Test indirect calls
	L		0
	T		MW 0
	L		1
	T		MW 50
	CLR
	UC		FC [MW 50]
	L		MW 0
	__ASSERT==	__ACCU 1,	W#16#6789
	L		0
	T		MW 0
	SET
	CC		FC [MW 50]
	L		MW 0
	__ASSERT==	__ACCU 1,	W#16#6789
	L		0
	T		MW 0
	CLR
	UC		FB [MW 50]
	L		MW 0
	__ASSERT==	__ACCU 1,	W#16#4321
	L		0
	T		MW 0
	SET
	CC		FB [MW 50]
	L		MW 0
	__ASSERT==	__ACCU 1,	W#16#4321

	__ASSERT==	__AR 2,		P#42.0 // Check AR2 magic


	// Test parameter forwarding (FB->FC)
	L		900
	T		MW 10
	CALL FB 10, DB 10 (
		INVAR1		:= TRUE,
		INVAR2		:= B#16#12,
		INVAR3		:= W#16#3456,
		INVAR4		:= DW#16#88776655,
		INVAR5		:= DB1.DBW 0,
		INVAR6		:= L#999999,
		INVAR7		:= 9.876,
		INVAR8		:= S5T#9s,
		INVAR9		:= T#9s,
		INVAR10		:= MW 10,
		INVAR11		:= 'c',
		RETURNVALUE	:= MW 0,
	)
	L		MW 0
	__ASSERT==	__ACCU 1,	99

	__ASSERT==	__AR 2,		P#42.0 // Check AR2 magic


	CALL SFC 46 // STOP CPU
END_ORGANIZATION_BLOCK
bues.ch cgit interface